How to use desktop high-speed refrigerated centrifuge

1. Turn on the power switch of the centrifuge and enter the standby state.

2. Choose a suitable rotor: during centrifugation, the liquid contained in the centrifuge tube cannot exceed 2/3 of the total volume, otherwise the liquid is easy

For overflow; before and after use, pay attention to whether there is any liquid residue in the rotor, and keep it dry. Convert

When turning the head, pay attention to make the bayonet of the centrifuge shaft and the head locked firmly.

2. The balance error of the centrifuge tube should be within 0.1 g.

3. Select the centrifugal parameters:

a) Press the temperature setting button, then use the numeric keys to set the centrifugal temperature, and press Enter to confirm.

b) Press the speed setting button to switch between RPM / RCF setting files, use the numeric keys to set the centrifugal speed,

Enter to confirm.

c) Press the rotor setting button, then use the numeric keys to set the rotor type, and press Enter to confirm.

d) Press the time setting button, then use the numeric keys to set the centrifugal time, and press Enter to confirm.

e) The brake or acceleration speed of the centrifuge is generally set between 0 and 4, and it should not be adjusted frequently.

4. Put the balanced centrifuge tube symmetrically into the rotor. Close the cover and tighten the screws.

5. Press the door of the centrifuge. If the door is not closed firmly, the centrifuge will not start.

6. Press the START button to start centrifugation. After centrifugation starts, wait for the centrifugal speed to reach the set speed before

Open, once the centrifuge is found to be abnormal (such as imbalance causing the machine to vibrate significantly, or the noise is very loud),

Should immediately press the STOP button, if necessary, directly press the power switch to cut off the power, stop centrifugation, and find out the cause.

7. If the machine finds a fault, please contact the relevant personnel in time.

8. After use, please clean the rotor and centrifuge cavity, do not close the centrifuge cover, which is conducive to moisture evaporation.

9. After use, you must register and indicate the use.

Precautions

1. When the centrifuge is in the pre-cooling state, the centrifuge cover must be closed. After the centrifuge is completed, the rotor should be taken out and placed upside down

On the experimental table, dry the remaining water in the cavity, and the centrifuge cover is open.

2. During ultracentrifugation, the liquid must be filled with the centrifuge tube, and vacuum should be used when it is separated from the ultracentrifuge.

Can avoid the deformation of the centrifuge tube. If the seal of the centrifuge tube is poor, the liquid cannot be filled up to prevent external

Overflow, affecting the normal operation of the sensor.

3. The rotor cover can be placed on the platform of the centrifuge when it is pre-cooled, or placed on the experimental table.

It can be floated on the rotor without tightening, because the rotor cover will fly out if it is accidentally started, causing an accident!

4. After the rotor cover is tightened, be sure to touch the finger with a seamless gap between the rotor and the cover, if there is a gap

Unscrew and retighten until the gap is confirmed before starting the centrifuge.

5. Be sure to ground the wire when using. The material added in the centrifuge tube should be relatively balanced, such as causing imbalance on both sides,

Will cause great damage to the centrifuge, at least will shorten the life of the centrifuge.

6. During the centrifugation process, the operator must not leave the centrifuge room.

To turn off the power (POWER), press STOP. Fill in the centrifuge use record before pre-cooling

We are professional manufacturer, which is established in 2005 and focus on export business to Euope, USA and Australia.

We specialized in producing various kinds of tissue products, including Family Box Tissue, Cube Box Tissue, Cylider car tissue, Mansize Box Tissue, Soft Pack tissue and Flat Pack Tissue etc. 

We provide customized service. We can make box at any size and shape as well as tissue size.

We supply different kinds of materials for cube Box Tissue , like Virgin wood pulp,  Recycled Pulp, Bamboo Pulp (Tree free).

The Material that we used are 100% biodegradable and compostable, Chlorine free and reach European food contact grade standard.

Cube Box Tissue

Tissue Paper Box,Cube Box Tissue,Square Tissue Box,Kleenex Box Tissue

Bobo Tissue Product Manufacturer , https://www.bobotissues.com