Instruction Manual of Rat Phenylalanine (LPA) ELISA Kit

This kit can only be used for scientific research, not for medical diagnosis.

Rat Phenylalanine (LPA) Quantitative Detection Kit (ELISA)

user's Guide

[Rat Phenylalanine (LPA) Elisa kit kit name]

Rat Phenylalanine (LPA) Quantitative Detection Kit (ELISA)

[Use of Rat Phenylalanine (LPA) Elisa Kit Kit]

Quantitative detection of phenylalanine (LPA) in rat serum, plasma and related liquid samples.

【Test principle of rat phenylalanine (LPA) Elisa kit】

This kit uses double-antibody two-step sandwich enzyme-linked immunosorbent assay (ELISA). Add the standard and the test sample to the pre-coated rat phenylalanine (LPA) monoclonal antibody transparent enzyme label coated plate. After incubation for a sufficient time, wash to remove unbound components and then add the enzyme label After incubation for a sufficient period of time, wash to remove unbound components. Substrates A and B were added in sequence, and the substrate (TMB) was converted into a blue product catalyzed by horseradish peroxidase (HRP), which turned yellow under the action of an acid. The concentration of lysine (LPA) was positively correlated. The OD value was measured at a wavelength of 450 nm. Based on the OD value of the standard and the sample, the content of rat phenylalanine (LPA) in the sample was calculated.

【Composition of rat phenylalanine (LPA) Elisa kit kit】

1

Enzyme coated plate

12 holes × 8

7

Developer A liquid

6mL

2

Standard

0.3mL × 6 tubes

8

Developer B liquid

6mL

3

20 times concentrated washing liquid

25mL

9

Stop solution

6mL

4

Sample diluent

6mL

10

Instructions

1 serving

5

Special diluent

6mL

11

Sealing film

2 sheets

6

Enzyme reagent

6mL

12

sealed bag

1

Remarks: The concentration of standard products (No. 1 → No. 6) is: 200, 100, 50, 25, 12.5, 6.25 pmol / L.

[Rat Phenylalanine (LPA) Elisa kit required but not provided reagents and equipment]

1. 37 ℃ thermostat

2. Standard specification microplate reader

3. Precision pipettes and disposable tips

4. Distilled water

5. Disposable test tubes

6. Absorbent paper

【Procedure for Rat Phenylalanine (LPA) Elisa Kit】

1. Preparation: Remove the reagent kit from the refrigerator and re-equilibrate at room temperature for 30 minutes.

2. Mixing solution: dilute the 20-fold concentrated washing solution with distilled water to the original one.

3. Add standard products and samples to be tested: take a sufficient number of enzyme-coated plates and fix them to the frame. Set up standard wells, test sample wells and blank control wells respectively. Add 50μL of standard product; first add 10μL of the sample to be tested, then add 40μL of sample diluent (that is, the sample is diluted 5 times); the blank control well is not added.

4. Incubation: Incubate in a 37 ° C water bath or thermostat for 30 minutes.

5. Wash the plate: discard the liquid, pat dry on the absorbent paper, fill each well with the washing liquid, let stand for 1min, shake off the washing liquid, pat dry on the absorbent paper, repeat the washing plate 4 times (you can also use the washing machine to press Instructions for washing the board).

6. Add enzyme-labeled working solution: add 50μL of enzyme-labeled working solution to each well, without adding blank control wells.

7. Incubation: Incubate in a 37 ° C water bath or thermostat for 30 minutes.

8. Plate washing: Discard the liquid, pat dry on the absorbent paper, fill each hole with the washing liquid, let stand for 1min, shake off the washing liquid, pat dry on the absorbent paper, repeat the plate washing 4 times (you can also use the washing machine to press Instructions for washing the board).

9. Color development: add 50μL of developer A solution to each well, and then add 50μL of developer B solution. Mix with a plate mixer for 30s (or shake gently by hand for 30s), and avoid color development at 37 ℃ for 15min .

10. Termination: Remove the enzyme labeling plate and add 50μL of stop solution to each well to stop the reaction (the color changes from blue to yellow)

11. Determination: Zero the blank holes, and within 15 minutes after termination, measure the absorbance (OD value) of each well with a wavelength of 450 nm.

12. Calculation: According to the concentration of the standard product and the corresponding OD value, calculate the linear regression equation of the standard curve, and then calculate the corresponding sample concentration on the regression equation according to the OD value of the sample. You can also use various application software to Calculation. The final concentration is the actual measured concentration times the dilution factor.

[Sample Requirements for Rat Phenylalanine (LPA) Elisa Kit]

1. The sample cannot contain sodium azide (NaN3) because sodium azide (NaN3) is an inhibitor of horseradish peroxidase (HRP).

2. The specimen should be extracted as soon as possible after collection. The extraction should be carried out according to relevant literature. If the test cannot be performed immediately, the specimen can be stored at -20 ℃, but repeated freezing and thawing should be avoided.

3. The sample should be fully centrifuged, without hemolysis and particles.

【Precautions for Rat Phenylalanine (LPA) Elisa Kit】

1. The experiment is carried out in strict accordance with the instructions, and the result of the experiment must be determined by the reading of the microplate reader.

2. If the enzyme-labeled coated board is not used up after opening, it should be put into a sealed bag and added with desiccant immediately.

3. It is recommended that all standards, samples and blank controls be tested in duplicate, and the average value is taken to reduce the experimental error.

4. Keep in mind that the sample has been diluted 5 times. The calculation result is multiplied by 5 to obtain the actual concentration of the sample.

5. The quantitative range of this kit is 6.25-200pmol / L. If it exceeds this range, it is calculated from the extension of the standard curve. ), Multiplied by the total dilution factor is the final concentration of the sample.

6. If the color is too light, the substrate incubation time can be extended properly.

7. In order to avoid cross-contamination, the tips, samples and blank controls should be replaced with a new one for each addition; the common components such as enzyme working solution, sample diluent and substrate should be cantilevered, and they should not touch the microwells. ; Do not reuse the sealing film.

8. The kits are used within the warranty period, and different batches of reagents should not be mixed.

9. Substrate B is sensitive to light and avoid prolonged exposure to light.

[Rat Phenylalanine (LPA) Elisa kit operating procedure summary]

Prepare reagents, samples and standards


Add prepared samples and standards, and react at 37 ℃ for 30 minutes

Wash the plate 4 times, add the enzyme reagent, and react at 37 ℃ for 30 minutes

Wash the plate 4 times, add color developing solutions A and B, and develop at 37 ℃ for 15 minutes

Add stop solution

Read OD value within 15 minutes

Calculation

[Rat Phenylalanine (LPA) Elisa kit detection range]

6.25pmol / L – 200pmol / L

【Specification of Rat Phenylalanine (LPA) Elisa Kit】

96 servings / box

【Storage of Rat Phenylalanine (LPA) Elisa Kit】

Store at 2-8 ℃, protected from light and moisture.

【Validity of Rat Phenylalanine (LPA) Elisa Kit】

6 months

JX BBQ is specialized in designing and producing of BBQ Grills over 10 years in China, with product categories of Outdoor Gas BBQ Grills, Charcoal Grills, Pizza Oven , Heating, Grill Tools And Accessories

Our Gas Grills range is with Full Size Gas Grill , Portable Gas Grill and Built-in Gas Grill. The Gas BBQ Grills are keep up to date with the latest standard of CE, CSA /UL, and AGA certificate. Exclusive Customized Design service is available here. From Concept & Design, 3D Structure modeling, CAM Prototyping, Tooling and Production, one stop shop of project management from design to stores. With a strong work team of technical design, complete project control, superior quality assurance and good after service, we are honor to be the BBQ Grills leading supplier in China. We are the reliable partner for you.